The heart of woman underwear brand since its inception, has been adhering to the "achievements beautiful woman" for the purposes of business, from product development, manufacturing, service, never pursued a woman's heart, keep making progress. "Heart of Women" series of underwear has always been in the Chinese civilization, the unique curve of cheongsam as the core creative graphics, designed to express a unique, simple atmosphere of the visual beauty, represents the charm and beauty of oriental women.

Fan Bingbing signed a "woman's heart", but also to the woman's brand underwear bring more vitality and visibility, I believe a woman's heart underwear will be dedicated to all the world's female friends to provide better products, services and beautiful

人生路相伴 女人心内衣最贴心

人生路相伴 女人心内衣最贴心

Surge Protection Device SPD

Product Description


SPD Surge Protective Device,Lightning Surge Protector

Surge Protection Device (SPD)

 

It is a device used to limiting instant surge voltage and discharge surge current, it at least including a non-linear component.

 

Surge protective Device Model Selection

 

With the impact of international information flow, the rapid development of microelectronic science and technology, communication, computer and automatic control technology, make the building start to go for high quality, high functional area, formed a new building style-intelligent building. As inside the intelligent building there are lot of information system, <> GB50057-94(2002 vision)(hereafter brief as <>) put forward the relative requirement to install the surge protective device, to ensure the information system safely and stable running.

SPD essentially is a equipotential connection material, its model selection is according to the different lightning protection area, different lightning electromagnetic pulse critical and different equipotential connection position, decide which kind of SPD used in the area, to achieve the equipotential connection with the common earth electrode. Our statement will based on SPD's maximum discharge current Imax, continuous operating voltage Uc, protection voltage Up, alarm mode etc.

As per << Lightning Protection Norm>> item 6.4.4 stipulation "SPD must can withstand the expected lightning current flow and should confirm to the additional two requirements: the maximum clamp voltage during surge across, capable to extinguish the power frequency follow-on current after lightning current across."  That is the value of SPD's max. clamp voltage add its induction voltage of two ends should be same with the system's basic insulation level and the equipment allowed max. surge voltage.

 

SPD for Power Supply System Series Selection Guide

 

The installation of SPD at each lightning protection zone, according to the standard of low voltage electrical appearance, make classification of electrical equipment in accordance with the over voltage category, its insulation withstand impulse voltage level can determine the selection of SPD. According to the standard of low voltage electrical appearance, make classification of electrical equipment in accordance with the over voltage category as signal level, loading level, distribution and control level, power supply level. Its insulation withstand impulse voltage level are:1500V,2500V,4000V,6000V. As per to the protected equipment installation position different and the different lightning current of different lightning protection zone, to determine the installation position of SPD for power supply and the break-over capacity.

The installation distance between each level SPD should not more than 10m, the distance between SPD and protected equipment should as short as possible, not more than 10m. If due to limitation of installation position, can't guarantee the installation distance, then need to install decoupling component between each level SPD, make the after class SPD can be protected by the prior class SPD. In the low voltage power supply system, connecting an inductor can achieve the decoupling purpose.

SPD for power supply system specification selection principle

Max. continuous operating voltage: bigger than protected equipment, the system's max. continuous operating voltage.

TT System: Uc≥1.55Uo (Uo is low voltage system to null line voltage)

TN System: Uc≥1.15Uo

IT System: Uc≥1.15Uo(Uo is low voltage system to line voltage)

Voltage Protection Level: less than the insulation withstand impulse voltage of protected equipment

Rated discharge current: determined as per to the lightning situation of the position installed and lightning protection zone.

SP1 Series

 

Normal Working Conditions

-Altitude not exceed 2000m

-Ambient air temperature:

Normal range: -5ºC~+40ºC

Extend range: -40ºC~+80ºC

-Relative Humidity: 30% - 90% under indoor temperature condition

- At the place without obviously shaking and shock vibration

- Non-explosion danger medium, non-corrosion gas and dust ( including conductive dust)

 

Classification

 

-As per Nominal Discharge Current:

5,10,20,30,40,60KA(8/20µs)

- As per Maximum continuous operating voltage:

275V,320V,385V,420V,440V,460V

- As per to poles

1P,1P+N,2P,3P,3P+N,4P

- As per auxiliary functions:

a. With remote signal output ( remote alarm function)

b. Without remote signal output

 

Selection Principle

 

- The continuous applied voltage on the two terminals of SPD should not more than the maximum continuous operating voltage Uc value;

- The voltage protection level Up of SPD should less than the maximum impulse withstand voltage of the protected equipment;

- As per to the different earthing system and protection mode to select the specification accordingly;

Product Features 

1, built-in over-current overheating, temperature control circuit technology.

2, the module design, easy installation, online replacement.

3, low leakage current, fast response time, low residual voltage.

4, alarm indication device, green (normal) v red (fault).

Model/Technical Parameters

WR-B60

WR-B80

WR-B100

WR-B120

WR-B150

Rated Operating Voltage Un (V ~)

220V 380V

220V 380V

220V 380V 

220V 380V  

220V 380V  

Maximum Continuous Operating Voltage Uc (V ~) kV

385V 420V

385V 420V

385V 420V 

385V 420V

385V 420V

Voltage Protection Level Up (V ~) kV

≤1.8≤2.2

≤2.4≤2.5

≤2.5≤3.2

 ≤3.4≤3.7 

≤4.0≤4.5

 Maximum Discharge

Current Imax(8/μ20μs)kA

60

80

100

120

150

Nominal Discharge

 Current In(8/μ20μs)kA

30

40

60

80

100

Response Time

<25

<100

L/N(mm²)The Cross Section Of L/N Line

16,25

16,25

16,25

16,25

25,35

 PE (mm²)The Cross Section Of PE Line

16,25

 25,35

 25,35

 25,35

35

Fuse or Switch (A)

 63A

 63A

 63A,100A

63A,100A

63A,125A

The Line Section of Communication and Alarm (mm²)

                                  ≥ 1.5   

Operating

Environment-C

                         (-40ºC~-+85ºC)

Relative humidity 25 ºC

                                  ≤95%

installation

Standard Rail35mm

Material of Outer Covering

Fiber Glass Reinforced Plastic

Surge Protector SPD,Surge Protection Device SPD,SPD