Pay attention to the suitability of choosing ppe Pay attention to the suitability of choosing ppe .

Pay attention to the suitability of choosing ppe

Clinical application of Uncaria

Clinical application

1, for the treatment of hypertension has a certain effect. According to more than 100 observations, the blood pressure of most patients decreased to varying degrees after taking the drug, and some of them could be reduced to the normal or near normal range. With the drop in blood pressure, symptoms such as dizziness, headache, palpitation, shortness of breath, insomnia and the like have also been reduced or disappeared. According to some case observations, the drop in blood pressure began 2-7 days after taking the drug. After 10 days, the antihypertensive effect is very significant, and it can sometimes continue to decline. The drop in blood pressure curve is ramp-like, indicating that the product has a mild effect. Individual cases have picked up during the medication but the fluctuations are very small and do not accompanied by worsening of symptoms.

2. The effect of neurological dysfunction is very significant. Symptoms can be significantly reduced by 5-10 days. The earlier the disease is, the better the effect is, and the third stage has no antihypertensive effect. However, in some patients, although there is no significant change in blood pressure, the symptoms are significantly improved. No side effects were seen in the treatment. Uغير مجاز مي باشدe: Unripe vine add water to boil for 10-20 minutes, make it into 20% concentration, 20-30ml each time, take 3 times daily; or use entwine 2 2 every day, put in boiling water to keep boiling point for 15-20 minutes, make Decoction 20Oml, in the evening service, 4-6 曰 for a course of treatment.

3. According to the traditional experience of the motherland, uncaria should not be decocted for a long time, otherwise it will affect the efficacy; modern pharmacology experiments also prove that when uncaria boiled for more than 20 minutes, the active ingredient of blood pressure is partially destroyed and the daily dose of 3-5 money is not satisfactory. With 2-2.5, the effect is better.


Patient Monitor

Features

10.1 inch high resolution color TFT display

Lightweight and portable design suitable for Ambulance,Emergency Transport

Three Working Modes : Monitoring , Surgery and Diagnosis.

Simple and friendly operating display interface.

Multi-display modes suitable for different applications: Standard Interface , Large font , ECG Standard Full Display ,OXY, Trend able BP Trend.

Built-in high capacity battery up to 3 hours of continuous work


Technique Specification

ECG

Lead Mode : 5 Leads ( I , ll , Ill , AVR , AVL , AVF , V )

Gain : 2.5mm / mV, 5.0mm /mV , 10mm /Mv,  20mm /mV

Heart Rate : 15-300 BPM ( Adult ) ; 15-350 BPM ( Neonatal )

Resolution : 1 BPM

Accuracy : ± 1%

Sensitivity > 200 uV ( Peak to peak )

ST measurement range : -2.0 ~+ 2.0 Mv

Accuracy : -0. 8mV~+ 0. 8mV : ± 0. 02mV or ± 10% , which is greater

Other Range : unspecified

Sweep speed : 12.5 mm / s , 25mm / s , 50mm / s

Bandwidth:

Diagnostic : 0.05~130 Hz

Monitor : 0.5~40 Hz

Surgery : 1~20 Hz


SPO2

Measuring Range : 0 ~ 100%

Resolution : 1%

Accuracy : 70%~100% ( ± 2 % )

Pulse Rate : 20-250 BPM

Resolution : 1 BPM

Accuracy : ± 3 BPM


Optinal Parameters :

Central monitoring system

Dual IBP

Etco 2

12-lead ECG

Nellcor SpO2

Sun Tech NIBP


NIBP

Method : Oscillometry

Measure mode Manual, Auto, STAT

Unit : mmHg , kPa

Measure and alarm range:

Adult Mode

   SYS    40 ~ 280 mmHg

   DIA    10 ~ 225 mmHg

   MEAN  20 ~ 240 mmHg


Pediatric Mode

   SYS 40 ~ 220 mmHg

   DIA 10 ~ 160 mmHg

   MEAN 20 ~ 170 mmHg


Neonatal Mode

   SYS 40 ~ 135 mmHg

   DIA 10 ~ 100 mmHg

   MEAN 20 ~ 110 mmHg

Resolution : 1 mmHg

Accuracy : ± 5 mmHg


TEMP

Measure and Alarm Range : 0 ~ 50 C

Resolution : 0 . 1C

Accuracy : ± 0 . 1C


Standard Parameters

ECG, RESP, TEMP, NIBP, SPO2, PR


RESP

Method : Impedance between RA-LL or RALA

Measurement Range:

Adult : 10~120 BrPM

Neonatal / Pediatric : 7~150 BrPM

Resolution : 1 BrPM

Accuracy : ± 2 BrPM


Standard Configuration

No                Item                                         Qty

  1. 1                Main Unit                                     1

  2. 2                5-lead ECG cable                         1

  3. 3                Disposable ECG Electrode           5

  4. 4                Adult Spo2 probe                        1

  5. 5                Adult NIBP cuff                            1

  6. 6                NIBP extension tube                    1

  7. 7                Temperature probe                      1

  8. 8                Power Cable                                 1

  9. 9                User Manual                                 1

  10. 10                Fuse                                             3

Patient Monitor,Portable Patlent Monltor,Patlent Monltor For Adult,Patlent Monltor For Baby

Guangzhou Sonostar Technologies Co., Limited , https://www.sonoeye.com


برچسب: ،
امتیاز:
 
بازدید:
+ نوشته شده: ۴ ارديبهشت ۱۴۰۱ساعت: ۰۶:۱۸:۱۲ توسط:Aramasque موضوع:

ارسال نظر
نام :
ایمیل :
سایت :
آواتار :
پیام :
خصوصی :
کد امنیتی :